The product
Trusted, and showing its age
PowerHMC has been around for years. Admins rely on it, and many of its screens were built long ago in a different style.
Enterprise UX · Product modernization
Re-examining complex infrastructure-management workflows from legacy interfaces toward a modern React and Carbon Design System experience.
| Location code | ID | Type | Link Status | MAC Address | Label | Sub-label | Configured Speed | Negotiated Speed | Available logical ports | Configured logical ports |
|---|---|---|---|---|---|---|---|---|---|---|
| U78D8.ND3.FD0022-P0-C0-T0 | 0 | RoCE | Down | B8:59:9F:EC:8D:F4 | Label | Sub-label | Auto | 25 Gbps | 40 | 0 |
| U78D8.ND3.FD0022-P0-C0-T1 | 1 | RoCE | Down | B8:59:9F:EC:8D:F4 | Label | Sub-label | Auto | 25 Gbps | 40 | 0 |
| (Device Name) Location code | Adapter ID | Physical Port ID | Capacity (%) | Type | Partition | VNIC Backed | Connected Partition | Permissions | Migratable |
|---|---|---|---|---|---|---|---|---|---|
| (unavailable) U78DA.ND0.WZS09FV | 2 | 0 | 2 | Ethernet | Content | Yes | VIOS1 | Diagnostic +1 | — |
| (unavailable) U78DA.ND0.WZS09FV | 2 | 0 | 2 | Ethernet | Content | Yes | VIOS2 | Diagnostic +1 | — |
The short version
What was wrong
The old screen showed nothing until you picked an item from a dropdown. Every change then opened a pop-up over the page you were on, and it never told you whether the change worked.
What we did
How we knew
I reviewed the old screens, talked to admins in four discovery sessions, and showed designs to them in three feedback sessions. Each design choice below points back to something a person said or did.
IBM Power servers run banks, airlines and phone companies. The administrators who look after them spend their days in PowerHMC, a dense control panel. When something here is confusing, the cost is real.
The product
PowerHMC has been around for years. Admins rely on it, and many of its screens were built long ago in a different style.
The challenge
The product was moving to a new look and technology. Our job was to improve the experience while keeping the tasks admins already know how to do.
My part
I studied the old screens, sketched and designed the new ones, tested ideas with admins, made decisions with engineers, and checked the finished build.
PowerHMC is the control panel for a Power server. To understand “Hardware virtualized I/O”, it helps to see who is connected to what.
PowerHMC was being rebuilt on a newer technology (React and the Carbon Design System), one screen at a time. This was one of those screens, and it was a good time to ask whether it worked for the people using it.
The page was empty until you picked an adapter from a dropdown. No overview, no status.
Every edit opened a dialog that covered the page you were working on.
No loading, no success, no error. Waiting looked the same as failing.
Understand
The issue
When an admin opens SR-IOV, they see a dropdown and a button. Nothing else. The entire page's instruction is: "Select the required SR-IOV adapter and click Modify." There is no overview, no status, no way to see all adapters at once without opening the list one by one.
Select the required SR-IOV adapter and click Modify to modify the properties of the SR-IOV adapter. The operating mode of the SR-IOV adapter and its owning partition name are also displayed.
Try it — pick an adapter. Until you do, the page tells you nothing.
The issue
Want to change an adapter from Shared mode to Dedicated? A modal appears over the page. It shows two radio buttons and grey OK / Cancel buttons. The modal covers the very port table you were just looking at. There's no visual weight to the primary action — OK looks the same as Cancel.
Mode changes — switching an adapter from Shared to Dedicated — are slow operations on the server. They can take time. But none of the legacy screens showed a loading state, a progress indicator, a success confirmation, or an error message. Users clicked OK and waited. They had no way to distinguish "it's running" from "it failed silently."
Select the required SR-IOV adapter and click Modify to modify the properties of the SR-IOV adapter. The operating mode of the SR-IOV adapter and its owning partition name are also displayed.
The table lists the properties of the SR-IOV adapter. You can change the mode of the SR-IOV adapter to either Dedicated or Shared.
| Location Code | ID | Description | Owner |
|---|---|---|---|
| U78D8.ND3.FD0022-P0-C3-C0 | 1 | PCIe3 2 PORT 10 GB NIC&ROCE | Hypervisor |
Configured Logical Ports : 0
Maximum Logical Ports : 80
Try it — press OK or Cancel in the dialog.
The issue
To modify a physical port: select a radio button → open an "Action" dropdown → click the only item inside it: "Modify Physical Port" → edit in yet another modal. There is also a separate "View" modal and a "Modify" modal for the same port — near-identical content, two different paths, easy to open the wrong one.
Select the required SR-IOV adapter and click Modify to modify the properties of the SR-IOV adapter. The operating mode of the SR-IOV adapter and its owning partition name are also displayed.
| ID | Location Code | Type | Link Status | MAC Address | |
|---|---|---|---|---|---|
| 0 | U78D8.ND3.FD0022-P0-C3-T0 | RoCE | Down | B8:59:9F:EC:8D:F4 | |
| 1 | U78D8.ND3.FD0022-P0-C3-T1 | RoCE | Down | B8:59:9F:EC:8D:F4 |
The issue
Near-identical content in two dialogs; users must learn two paths to one object and may open the wrong one.
Select the required SR-IOV adapter and click Modify to modify the properties of the SR-IOV adapter. The operating mode of the SR-IOV adapter and its owning partition name are also displayed.
| ID | Location Code | Type | Link Status | MAC Address | |
|---|---|---|---|---|---|
| 0 | U78D8.ND3.FD0022-P0-C3-T0 | RoCE | Down | B8:59:9F:EC:8D:F4 | |
| 1 | U78D8.ND3.FD0022-P0-C3-T1 | RoCE | Down | B8:59:9F:EC:8D:F4 |
You can view the properties of a physical port that is on a Single Root I/O Virtualization (SR-IOV) capable adapter. The table lists the details of the physical port that you want to view.
| ID | Location Code | Type | Link Status | Available Logical Ports | Configured Logical Ports |
|---|---|---|---|---|---|
| 0 | U78D8.ND3.FD0022-P0-C3-T0 | RoCE | Down | 40 Ethernet | 0 Ethernet |
Same port, two dialogs. Switch between them and spot the difference.
Investigate & prioritize
The project included four discovery sessions and three design-feedback sessions. These weren't exclusively about SR-IOV — they covered the broader feature context. But several signals landed directly on what I was designing.
Listen. How admins work and how they experience the old screens.
Map. Each person's day-to-day, turned into needs and frustrations.
Scope. Agreed with product managers and engineers what to take on, and why anything was left out.
Return. Polished designs, shown to the same people.
Try. We gave them tasks, watched what they did and asked questions.
Improve. What we learned went straight back into the design.
“Rarely modify after initial setup. VLAN tagging and bandwidth allocation are the key settings.”Discovery user 2
“This is definitely better.”Feedback user 2, comparing the adapter table with the old dropdown
“…would be nice to have a link status / negotiated speed shown, e.g., 10G or 25G, so we know if there is an issue or degradation.”Feedback user 2, on the physical port view
“I’m not very happy with the responsiveness… it’s complex to see which step the transfer is in.”Feedback user 1, on changing shared to dedicated
Design & deliver
The solution
The old page was blank until you chose. You couldn't compare adapters, see their status, or understand which one needed attention without working through the dropdown one entry at a time.
The redesign lands directly on a table. All adapters, with their mode, status and location code visible at once.
| Location code | SR-IOV adapter ID | Mode | Maximum Logical Ports | Available logical ports | Configured logical ports | Description | Owner | Status | Adapter configuration option | |
|---|---|---|---|---|---|---|---|---|---|---|
| U78D8.ND3.FD0022-P0-C3-C0 | 1 | Dedicated | NA | NA | NA | PCIe3 2 PORT 10GB NIC&ROCE | Hypervisor | Running | Not Supported | |
| U78D8.ND3.FD0022-P0-C3-C1 | 2 | Dedicated | NA | NA | NA | PCIe3 2 PORT 10GB NIC&ROCE | Hypervisor | Running | Not Supported | |
| U78D8.ND3.FD0022-P0-C3-C2 | 3 | Shared | 70 | 0 | NA | PCIe3 2 PORT 10GB NIC&ROCE | Hypervisor | Running | Not Supported |
Try it — search, or click a row to select an adapter.
The solution
The redesign opens a right-hand side panel from a selected row. The table stays visible. The Cancel and Save buttons are pinned to the bottom — they never scroll away.
The redesign treats each state as a first-class design problem: skeleton loading, a missing-adapter warning with disabled fields, an in-progress state with a progress bar and estimated duration, and explicit error and success outcomes.
| Location code | SR-IOV adapter ID | Mode | Maximum Logical Ports | Available logical ports | Configured logical ports | Description | Owner | Status | Adapter configuration option | |
|---|---|---|---|---|---|---|---|---|---|---|
| U78D8.ND3.FD0022-P0-C3-C0 | 1 | Shared | NA | NA | NA | PCIe3 2 PORT 10GB NIC&ROCE | Hypervisor | Running | Not Supported | |
| U78D8.ND3.FD0022-P0-C3-C1 | 2 | Dedicated | NA | NA | NA | PCIe3 2 PORT 10GB NIC&ROCE | Hypervisor | Running | Not Supported | |
| U78D8.ND3.FD0022-P0-C3-C2 | 3 | Shared | 70 | 0 | NA | PCIe3 2 PORT 10GB NIC&ROCE | Hypervisor | Running | Not Supported |
Click any table row to reopen the panel. In Edit, change the mode to enable Save. Press Esc to close.
The solution
On the adapter page, both sections used to expand by default. This pushed content down and created visual noise.
I chose to expand Physical ports and collapse Logical ports — because research suggested logical-port creation is done at partition level, and admins change them infrequently. Physical ports are the more common working context.
| Location code | ID | Type | Link Status | MAC Address | Label | Sub-label | Configured Speed | Negotiated Speed | Available logical ports | Configured logical ports |
|---|---|---|---|---|---|---|---|---|---|---|
| U78D8.ND3.FD0022-P0-C0-T0 | 0 | RoCE | Down | B8:59:9F:EC:8D:F4 | Label | Sub-label | Auto | 25 Gbps | 40 | 0 |
| U78D8.ND3.FD0022-P0-C0-T1 | 1 | RoCE | Down | B8:59:9F:EC:8D:F4 | Label | Sub-label | Auto | 25 Gbps | 40 | 0 |
| (Device Name) Location code | Adapter ID | Physical Port ID | Capacity (%) | Type | Partition | VNIC Backed | Connected Partition | Permissions | Migratable |
|---|---|---|---|---|---|---|---|---|---|
| (unavailable) U78DA.ND0.WZS09FV | 2 | 0 | 2 | Ethernet | Content | Yes | VIOS1 | Diagnostic +1 | — |
| (unavailable) U78DA.ND0.WZS09FV | 2 | 0 | 2 | Ethernet | Content | Yes | VIOS2 | Diagnostic +1 | — |
Try it — expand or collapse Physical ports and Logical ports.
Visible
The old screens stayed silent after a click. Now you see loading, progress, errors and success as they happen.
Findable
Adapters used to hide behind a dropdown. Now they are all listed in one table, including their real link speed.
Direct
It took a radio button, a one-item menu and a pop-up to reach a port. Now it is one link.
In context
Pop-ups used to cover the table you were editing. A side panel now sits beside it, so the page stays in view.
Consistent
Two different looks used to be mixed on the same page. Now the buttons, tables and wording match throughout.
Focused
Port details used to be buried. Now each port has its own page, so you can see everything about it in one place.
Based on a heuristic review of legacy screens against the redesign. Not a usability test.
The lessons I am taking with me, and where this goes after the first release.
What I learned
Working closely with Product Managers and Engineering from the start helped me understand what the business needed, what was possible, and how much to take on at once.
Sponsor user research
Admins told us they wanted adapter details up front, clickable IDs and the real link speed. Listening closely paid off.
What I'd do differently
Loading and error screens came late. Next time I would design them right alongside the happy path, not after it.
What's next
Bring the same side panel and feedback ideas to the rest of PowerHMC, and check the shipped experience with real users.